TEST ID ZN_S Zinc, Serum
Reporting Name
Zinc, SSpecimen Type
SerumSpecimen Required
Patient Preparation: High concentrations of gadolinium, iodine, and barium are known to interfere with most metal tests. If gadolinium-, iodine, or barium-containing contrast media has been administered, the specimen should not be collected for 96 hours.
Supplies:
-Metal Free Specimen Vial (T173)
-Metal Free B-D Tube (No Additive), 6 mL (T184)
Collection Container/Tube: 6-mL Plain, royal blue-top Vacutainer plastic trace element blood collection tube
Submission Container/Tube: 7-mL Mayo metal-free, screw-capped, polypropylene vial
Specimen Volume: 0.8 mL
Collection Instructions:
1. This specimen must always be drawn first.
2. Do not collect specimen from a line.
3. Allow the specimen to clot for 30 minutes; then centrifuge the specimen to separate serum from the cellular fraction. Serum must be removed from cellular fraction within 4 hours of specimen collection. Avoid hemolysis.
4. Remove the stopper. Carefully pour specimen into a Mayo metal-free, polypropylene vial, avoiding transfer of the cellular components of blood. Do not insert a pipet into the serum to accomplish transfer, and do not ream the specimen with a wooden stick to assist with serum transfer.
5. See Metals Analysis Specimen Collection and Transport for complete instructions.
Specimen Minimum Volume
0.2 mL
Specimen Stability Information
Specimen Type | Temperature | Time | Special Container |
---|---|---|---|
Serum | Refrigerated (preferred) | 28 days | METAL FREE |
Ambient | 28 days | METAL FREE | |
Frozen | 28 days | METAL FREE |
Special Instructions
Method Name
Dynamic Reaction Cell-Inductively Coupled Plasma-Mass Spectrometry (DRC-ICP-MS)
Reject Due To
Gross hemolysis | Reject |
Gross lipemia | OK |
Gross icterus | OK |
Reference Values
0-10 years: 60-120 mcg/dL
11-17 years: 66-110 mcg/dL
≥18 years: 60-106 mcg/dL
Day(s) Performed
Monday through Saturday
Report Available
1 to 3 daysSpecimen Retention Time
14 daysPerforming Laboratory
Mayo Clinic Laboratories in RochesterCPT Code Information
84630
Forms
If not ordering electronically, complete, print, and send General Test Request (T239) with the specimen.
Useful For
Detecting zinc deficiency