TEST ID LKM Liver/Kidney Microsome Type 1 Antibodies, Serum
Reporting Name
Liver/Kidney Microsome Type 1 Ab, SSpecimen Type
SerumSpecimen Required
Supplies: Sarstedt Aliquot Tube, 5 mL (T914)
Collection Container/Tube:
Preferred: Serum gel
Acceptable: Red top
Submission Container/Tube: Plastic vial
Specimen Volume: 0.5 mL
Collection Instructions: Centrifuge and aliquot serum into a plastic vial.
Specimen Minimum Volume
0.4 mL
Specimen Stability Information
Specimen Type | Temperature | Time | Special Container |
---|---|---|---|
Serum | Refrigerated (preferred) | 21 days | |
Frozen | 21 days |
Special Instructions
Testing Algorithm
For more information see First-Line Screening for Autoimmune Liver Disease Algorithm.
Method Name
Enzyme-Linked Immunosorbent Assay (ELISA)
Reject Due To
Gross hemolysis | Reject |
Gross lipemia | Reject |
Gross icterus | OK |
Heat treated | Reject |
Reference Values
≤20.0 Units (Negative)
20.1-24.9 Units (Equivocal)
≥25.0 Units (Positive)
Reference values apply to all ages.
Day(s) Performed
Monday, Wednesday, Friday
Report Available
2 to 4 daysSpecimen Retention Time
14 daysPerforming Laboratory
Mayo Clinic Laboratories in RochesterCPT Code Information
86376
Forms
If not ordering electronically, complete, print, and send 1 of the following with the specimen:
-Gastroenterology and Hepatology Test Request (T728)
-General Request (T239)
Useful For
Evaluation of patients with liver disease of unknown etiology
Evaluation of patients with suspected autoimmune hepatitis