Sign in →

TEST ID HIVc HIV COMBO-ANTIBODY/ANTIGEN QUALITATIVE (HIV 1 & 2 IgM/IgG ab and p24 ag)REFLEX CONFIRMATION

Important Note

Fourth generation assays simultaneously detect HIV-1 and 2 IgM/IgG antibodies, as well as p24 antigen.

Performing Laboratory

NRLS-Core Chemistry

Specimen Type

Serum and Plasma

*Plasma is needed if reflex confirmation testing is required.

Specimen Required

Container/Tube:
Preferred: Serum Gel Gold top
Acceptable: Red top, Lavender EDTA
Specimen Volume: 1.5 mL

Collection Instructions:
Serum gel tubes should be fully clotted and centrifuged within 2 hours of collection. 4 hours is acceptable.
Red-top tubes should be fully clotted, centrifuged and aliquoted within 2 hours of collection.4 hours is acceptable.

 

*Container/Tube:
Preferred: Lavender EDTA
Acceptable:
Specimen Volume: 1.5 mL

Collection Instructions:

  1. Centrifuge and aliquot within 2 hours of collection.
  2. Aliquot plasma into plastic vial.

Specimen Minimum Volume

1.0 mL

Specimen Stability Information

Specimen Type

Temperature

Time

Serum/Plasma-COMBO Refrigerated(preferred) 7 days
  Ambient 24 hours
  Frozen Indefinite
Plasma-Confirm Reflex Refrigerated 6 days
  Ambient NOT Acceptable
  Frozen(preferred) 30 days

 

Reference Values

An interpretive report will be provided

Reflex Test

All non negative specimens will be resulted as "Sent Out" and sent to Mayo for confirmation.

Test ID Reporting Name Available
Separately
Always
Performed
HIVDIP HIV-1 and HIV-2 Antibody Confirmation and Differentiation Yes No